Skip to main content

Table 1 Relationship between pump and ventilator setting and various data

From: Integrative respiratory support during thoracoabdominal aortic aneurysm repair in a patient with severe lung disease: a case report

Pump

Setting

Before CPB

CPB

VV-ECMO

After VV-ECMO

Mean flow rate (L/m)

-

3.4

2.1

-

Ventilator

Setting

PCV

PCV

PCV

PCV

PEEP (mmHg)

4

4

4

4

Airway pressure (mmHg)

16

12

19

19

Median tidal volume (mL)

363 (361–376)

131 (111–178)

259 (226–314)

321 (321–321)

RR(/min)

12

8

12

12

FiO2 (%)

100

60

100

60

Arterial gas

Mean PaO2 (mmHg)

561

305

425

217

Mean PaCO2 (mmHg)

49

42

38

54

  1. CPB Cardio-pulmonary bypass, VV-ECMO Veno-venous extracorporeal membrane oxygenation, PCV Pressure control ventilation, PEEP Positive end-expiratory pressure, RR Respiration rate